Idec DATAVS2 Series User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 83
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
Instruction Manual SVS2 Series
26
Open the pull-down menu to display the different Output Modes.
Output is Disabled by default.
The other options are:
Toggle: Output toggles between logic values 1 and 0;
Part Pass: Inspection as a whole is considered. The statuses of individual controls are taken into
account: the output acts as the logic AND for these statuses (in other words, the output will only
be Pass when all involved controls return a Pass result);
Part Fail: Inspection as a whole is considered. The statuses of individual controls are taken into
account: the output acts as the logic NAND for these statuses (in other words, the output will only
be OK when at least one of the involved controls returns a FAIL result);
BusyReady: Output may take on logic values 1 and 0;
Error: Indicates an error in the inspection.
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 82 83

Comments to this Manuals

No comments